Bell System bellview Especificaciones Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
Bell View Video Entry System 1 Way
15
Miscellaneous Problems
Telephone will not buzz. ! Buzzer disabled by PRIVATE button. Check red
telephone LED is off.
! Faulty ‘V’,'O' or 'I' line between power supply and
phone. Check 10V - 15V across ‘V’ and ‘O’, and
10V - 15V across ‘I’ and ‘O’ when called.
! Faulty panel button.
Telephone ‘DOOR’ button does not
operate release.
! Telephone is not live.
! Fault on 'Z' or 'O' line. Check shorting 'Z' to 0V at
the M540 power supply, when live, operates the
release.
! Lock release supply low. Check 10V-15V across
the release with the lock button pressed and the
phone live.
! Faulty ‘DOOR’ button on telephone.
Lock release operates all the time. ! If the lock is a 'fail safe' type it has been connected
to 'FAIL SECR'/'fail secure' output. If the lock is a
'fail secure' type it has been connected to 'FAIL
SAFE' /'fail safe' output. Check to see if the
release is inactive when the lock button is pressed
or try swapping the connections over.
! ‘DOOR’ button stuck down (lock operates only
when live).
! 'Z' and 'O' lines permanently shorted together.
Supply voltage low (less than 10V,
any system component).
! Short circuit. Disconnect power supply loads and
check the output is 12V - 15V. Systematically
disconnect components one at a time or isolate
floors, etc. until the voltage is correct. Start with
connections close to the Power Supply.
! Cable voltage drop too high. Try doubling wires up
with spare cores. Refer to the Cable and Wiring
Details sections.
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 26 27

Comentarios a estos manuales

Sin comentarios