bellissimo 1 Way Video Entry System
Installation and Operating Manual Page 25 of 25
Important Safety Information
Connections to the 240VAC mains supply must be carried out by a qualified
electrician or similar competent person, and made in accordance with current
legislative requirements. A two-pole switch (as provided by a Consumer Unit or
Switch-Fuse) must be included to isolate both Live and Neutral during Installation or
Maintenance. The circuit must be protected by a fuse or other current-limiting device,
rated according to the capacity of the cable used, up to a maximum of 10A. Use only
mains cable to BS6004 or equivalent, within the following specified limits:
Min Max
Conductor Diameter
1.0mm (0.8mm
2
)
2.25mm (4mm
2
)
Cable Diameter 4.0mm 8.0mm
Model 840 PSU (with battery standby)
The Model 840 PSU must be placed in a protected indoor environment such as an
electrical cupboard. It must be secured to the wall with adequate fixings so that there
is no possibility of it falling. The Lead-Acid Battery for the Standby Power Supply is
shipped in separate packaging. It should only be connected once the system has
been fully tested. Connection is made by 2 leads with spade terminals; observe the
correct polarity - red to positive, black to negative. Care must be taken to ensure that
the terminals of the battery are not shorted together by metal objects, as this may
constitute a Fire Hazard. The Control Cabinet is IP55 rated (to exclude dust) and is
vented to avoid the build-up of gases. Do not block any vents that may be apparent.
A good mains safety earth must be connected to the cabinet housing the power
supply
Where the power supply is fitted with a replaceable internal mains fuse and or battery
fuse, always replace with the same type as indicated on the power supply. The fuse
must be approved to BS EN 60127 or equivalent.
Power Supply Model
Mains Fuse (Time Delay) Battery Fuse (Quick Blow)
840 T2A 20mm HBC (HRC) Ceramic
F4A 20mm Glass
Model PS4 and 340C Power Supplies
These power supplies must be wall-mounted onto plasterboard, or a similar non-
conductive material, in a protected indoor environment such as an electrical
cupboard.
When fitting the power supply cable (both mains and low voltage) ensure the cable
entry cut-outs in the enclosure lid are no larger than necessary for the cable diameter
used and under no circumstances must they be taken beyond the outer cut-out
zones.
Videophone
The display module of the videophone has a high voltage circuit (2KV), which
represents a shock hazard. Do not remove the inner cover of the videophone
assembly, there are no user adjustments requiring this.
Comentarios a estos manuales