CS106/BL106 Combined Door Entry and Coded Access
15
Time Restricted Access
The C105 Keypad has a pair of terminals marked ‘TIME’ which can be
connected to an external Time Clock or Key switch to control time-restricted
access. Any switch contact must be fully isolated (i.e. voltage free), the
TS2000-BST Time Clock is normally used.
Access codes may be programmed as follows:
Access
Time Switch Status
Usage
No Restriction - Executive
Zone 1 Contact Closed Staff (shift 1)
Zone 2 Contact Open Staff (shift 2)
Exit Button
The terminal marked ‘EXIT’ may be connected to an external push-button (e.g.
5077 switch) for ‘push to exit’ operation. Momentarily operating this button will
directly operate the lock release for the programmed duration.
Alternatively, the input may be used with a Fireman’s Override key-switch,
which should be of the normally-open type. If this feature is to be used it is
important that the lock release be of a continuously-rated design.
In general, a switch connected to the ‘EXIT’ terminals should be fully isolated i.e.
Voltage-free.