Bell System BL106 Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
CS106/BL106 Combined Door Entry and Coded Access
29
Testing the controller with factory settings
Before proceeding with this test ensure that the lock release is working correctly
by following the tests on page 28.
Program to factory settings by following the instructions on page 24 or 32.
Type in code 1 (1 2 3 4 5) - this should operate the lock release for 3
seconds.
If a time clock is present on the system, manually switch it to OFF and
type code 2 (6 7 8 9 0), nothing should happen. Now manually switch the time
clock to ON and retype code 2 (6 7 8 9 0) - the lock release should operate for 3
seconds.
Reprogram code 1 to another value by following the instructions under
the heading ‘Programming a new access code’ (page 17); check that the new
code operates the lock release and that the old one does not.
If everything is functioning correctly, reprogram the security key (factory
set to 1212), to maintain security.
Reprogram access codes, action codes and other parameters as
required (pages 16 to 24).
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 47 48

Comentarios a estos manuales

Sin comentarios