Bell System bell free Manual de usuario Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
34
Bell res
English
Instructions for use and installation instructions
3.5 POSITIONING THE APPLIANCE AND ORNAMENTAL HOOD
Important: The appliance may only be installed on a wall
constructed from non-fl ammable material.
To suspend the appliance, use the correct fi xing
method appropriate to the wall in question.
The total weight of the appliance and ornamental
hood is 70kg.
Flammable materials, such as curtains, should not
be placed in the vicinity of the gas fi re.
Minimum safe distance: 100 cm
Position the gas supply pipe so that it can easily be installed after suspending the
appliance.
(*) : Color: RVS: Stainless steel self-colour, polished
antr.: Anthracite colour lacquer, matt
(**) : Adjustable roof fl ashing for a slope > 45° can be supplied on request.
When installing a balanced-fl ue “closed” gas fi re in an existing chimney, ensure stain-
less steel fl exible liners conforming with BS 316 are used to conduct the spent gases.
The room-sealed gas appliances have been approved in combination with
the BARBAS (RIGID and FLEXIBLE) CONCENTRIC FLUE SYSTEM
Ø100 mm - Ø150 mm according to the European CE norm for gas appliances
and may therefore be used only in combination with this fl ue system.
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 55 56

Comentarios a estos manuales

Sin comentarios